Lowrise houses with flat roof
- Breadth : Depth : Height = 16m : 16m : 4m
- Considered load effect for members:
Axial force, Shear forces (2 component), Moments (except torsional moment)
- Wind direciton : 0 degree
|
|
Lowrise houses with flat roof
- Breadth : Depth : Height = 16m : 16m : 8m
- Considered load effect for members:
Axial force, Shear forces (2 component), Moments (except torsional moment)
- Wind direciton : 0 degree
|
|
Lowrise houses with flat roof
- Breadth : Depth : Height = 16m : 16m : 12m
- Considered load effect for members:
Axial force, Shear forces (2 component), Moments (except torsional moment)
- Wind direciton : 0 degree
|
|
Lowrise houses with flat roof
- Breadth : Depth : Height = 16m : 16m : 16m
- Considered load effect for members:
Axial force, Shear forces (2 component), Moments (except torsional moment)
- Wind direciton : 0 degree
|
|
Lowrise houses with flat roof
- Breadth : Depth : Height = 16m : 24m : 4m
- Considered load effect for members:
Axial force, Shear forces (2 component), Moments (except torsional moment)
- Wind direciton : 0 degree
|
|
Lowrise houses with flat roof
- Breadth : Depth : Height = 16m : 24m : 8m
- Considered load effect for members:
Axial force, Shear forces (2 component), Moments (except torsional moment)
- Wind direciton : 0 degree
|
|
Lowrise houses with flat roof
- Breadth : Depth : Height = 16m : 24m : 12m
- Considered load effect for members:
Axial force, Shear forces (2 component), Moments (except torsional moment)
- Wind direciton : 0 degree
|
|
Lowrise houses with flat roof
- Breadth : Depth : Height = 16m : 24m : 16m
- Considered load effect for members:
Axial force, Shear forces (2 component), Moments (except torsional moment)
- Wind direciton : 0 degree
|
|
Lowrise houses with flat roof
- Breadth : Depth : Height = 16m : 40m : 4m
- Considered load effect for members:
Axial force, Shear forces (2 component), Moments (except torsional moment)
- Wind direciton : 0 degree
|
|
Lowrise houses with flat roof
- Breadth : Depth : Height = 16m : 40m : 8m
- Considered load effect for members:
Axial force, Shear forces (2 component), Moments (except torsional moment)
- Wind direciton : 0 degree
|
|
Lowrise houses with flat roof
- Breadth : Depth : Height = 16m : 40m : 12m
- Considered load effect for members:
Axial force, Shear forces (2 component), Moments (except torsional moment)
- Wind direciton : 0 degree
|
|
Lowrise houses with flat roof
- Breadth : Depth : Height = 16m : 40m : 16m
- Considered load effect for members:
Axial force, Shear forces (2 component), Moments (except torsional moment)