Aerodynamic Databese of High-rise Buildings |
Test model case | |
Model geometric parameters | |
Breadth/Depth/Height=100:100:200; Model scale=1/400 | |
Pressure tap locations | |
Figure--> |
Wind tunnel test result |
Contours of local wind pressure coefficients |
Wind direction | 0o | 5o | 10o | 15o | 20o | 25o | 30o | 35o | 40o | 45o | 50o |
---|---|---|---|---|---|---|---|---|---|---|---|
Mean values | |||||||||||
RMS values | |||||||||||
Max values | |||||||||||
Min values |
Graphs of area-average wind pressure coefficients |
Windward surface | Right sideward surface | leeward surface | Left sideward surface |
---|---|---|---|
Time series of point wind pressure coefficients (Data files) |
Wind direction | 0o | 5o | 10o | 15o | 20o | 25o | 30o | 35o | 40o | 45o | 50o |
---|---|---|---|---|---|---|---|---|---|---|---|
Data files(.mat) |